Коды ошибок для Canon ir1018/1019/1022/1023

Code Cause Remedy
E000 Startup error
0 The temperature detected by the main or sub thermistor does not rise to the specified value during startup control. Check the fixing film connector.
Replace the fixing film unit.
Replace the DC controller PCB.
E001 Abnormally high temperature
0 Abnormally high temperature (detected by main thermistor) Check the connector of the fixing film unit.
The main thermistor detected an abnormally high temperature (235 deg C) during temperature control. Replace the fixing film unit.
1 Abnormally high temperature (detected by sub thermistor) Replace the DC controller PCB.
The sub thermistor detected an abnormally high temperature (300 deg C) during temperature control.
E002 Low temperature during temperature control.
0 The target temperature is not reached during temperature control. Check the connector of the fixing film unit.
Replace the fixing film unit.
Replace the DC controller PCB.
E003 Abnormally low temperature
0 Abnormally low temperature (detected by main thermistor) Check the connector of the fixing film unit.
After the temperature detected by the main thermistor has reached the specified value, it does not reach the specified value during initial rotation. Replace the fixing film unit.
1 Abnormally low temperature (detected by sub thermistor) Replace the DC controller PCB.
After the temperature detected by the sub thermistor has reached the specified value, it does not reach the specified value during initial rotation.
E010 Main motor failure
0 The main motor is faulty. Check the connector of the main motor.
Replace the main motor.
Replace the DC controller PCB.
E019 Waste toner full detection
0 The waste toner full state was detected. Replace the drum unit
1 Waster toner full detection sensor is faulty. Check the connector of the waster toner full sensor.
The waste toner full state was detected continuously for five or more seconds while the main motor was turning. Replace the waste toner full sensor.
Replace the DC controller PCB.
E100 BD detection PCB failure
0 The BD detection PCB is faulty. Check the connector of the BD detection PCB.
Replace the laser scanner unit.
Replace the DC controller PCB.
E196 Flash ROM write/read error
1 The write/read of Flash ROM in the image processor PCB is faulty. Replace the image processor PCB.
2 PCL ROM write/read error Replace the PCL PCB.
The write/read of PCL ROM in the image processor PCB is faulty. Replace the image processor PCB.
E197 Printer engine communication error
0 Erroneous communication between the DC controller PCB and image processor PCB was detected. Check the connectors of the DC controller PCB and image processor PCB.
Replace the DC controller PCB for normal connection.
Replace the image processor PCB.
E716 Erroneous communication with optional cassette
0 Disconnection of the optional cassette was detected after power-on, detection of normal connection to the optional cassette, and start of communication. Check the connectors of the optional cassette PCB and DC controller PCB.
Replace the optional cassette PCB for normal connection.
Replace the DC controller PCB.
E719 Erroneous communication
0 Erroneous communication with card reader (serial communication) Check the connectors of the card reader and image processor PCB.
1. Disconnection from the card reader has been detected since communication started after confirmation of normal connection to the card reader (after power-on). Replace the card reader for normal connection.
2. A serial communication error has occurred. (The serial communication error cannot be recovered.) Replace the image processor PCB.
1 Erroneous communication with coin vendor (serial communication) Check the connection between the image processor PCB and serial PCB.
1. Disconnection from the coin vendor has been detected since communication started after confirmation of normal connection to the coin vendor (after power-on). Check the connectors of the serial PCB and coin vendor for normal connection.
2. A serial communication error has occurred. (The serial communication error cannot be recovered.) Replace the serial PCB.
Check the coin vendor.
Replace the image processor PCB.
E730 Inside error of the image processor PCB (PDL system error)
0 The inside of the image processor PCB is faulty. Replace the image processor PCB.
E733 Erroneous communication between controller and printer
0 Cannot communicate with the printer at startup. Check the connectors of the DC controller PCB and image processor PCB for normal connection.
Check the power supply of the printer (Check whether initialization is performed at startup).
Replace the DC controller PCB or image processor PCB.
E736 CCU communication error
0 The installed modem PCB is incompatible. Check the connectors of the image processor PCB and modem.
Replace the modem PCB.
Replace the image processor PCB.
E739 Erroneous communication between controller and network board
0 The installed network board is incompatible. Check the connectors of the image processor PCB and LAN PCB for normal connection.
Replace the LAN PCB.
Replace the image processor PCB.
E805 Fan failure
0 The fan is faulty. Check the fan connector.
Replace the fan.
Replace the DC controller PCB.
E808 Fixing drive circuit failure
0 1. The heater does not turn on. Check the connector of the fixing film unit.
2. A fixing drive motor failure was detected. Replace the fixing film unit.
Replace the fixing drive motor.
Replace the DC controller PCB.
Replace the power supply PCB.